Figure 48-13
command using the object OIDs. In both cases, the object is followed by same index number used in the
snmpset
Figure 48-13. Obtaining MIB Object Values for a Copy Operation using Object-name Syntax
> snmpget -v 2c -c private -m ./f10-copy-config.mib 10.11.131.140 copyTimeCompleted.110
FORCE10-COPY-CONFIG-MIB::copyTimeCompleted.110 = Timeticks: (1179831) 3:16:38.31
Figure 48-14. Obtaining MIB Object Values for a Copy Operation using OID Syntax
> snmpget -v 2c -c private 10.11.131.140 .1.3.6.1.4.1.6027.3.5.1.1.1.1.13.110
SNMPv2-SMI::enterprises.6027.3.5.1.1.1.1.13.110 = Timeticks: (1179831) 3:16:38.31