Figure 50-21. Recovering from a Stack Link Flapping Error
--------------------------------------MANAGMENT UNIT-----------------------------------------
Error:
Stack Port 50 has flapped 5 times within 10
ack port now.
Error: Please check the stack cable/module and power-cycle the stack.
10:55:20: %STKUNIT1-M:CP
ithin 10 seconds.Shutting down this stack port now.
10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module
and power-cycle the stack.
---------------------------------------STANDBY UNIT------------------------------------------
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times within 10
seonds.Shutting down this stack port now.
10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module
and power-cycle the stack.
----------------------------------------MEMBER 2---------------------------------------------
Error: Stack Port 51 has flapped 5 times within 10 seconds.Shutting down this stack port now.
Error: Please check the stack cable/module and power-cycle the stack.

Recover from a Card Problem State on an S-Series Stack

If a unit added to a stack has a different FTOS version, the unit does not come online, and FTOS cites a
card problem error, as shown in
the FTOS version to match the stack, and then reconnect it to the stack.
Figure 50-22. Recovering from a Card Problem Error on an S-Series Stack
F
Stack#show system brief
Stack MAC : 00:01:e8:d5:f9:6f
--
Stack Info
--
Unit
UnitType
Status
---------------------------------------------------------------------------
0
Member
card problem
1
Management
online
2
Standby
online
3
Member
not present
4
Member
not present
5
Member
not present
6
Member
not present
7
Member
not present

Recover from a Card Mismatch State on an S-Series Stack

A card mismatch occurs if the stack has a provision for the lowest available stack number which does not
match the model of a newly added unit
remove the provision from the stack, then reconnect the standalone unit, or
renumber the standalone unit with another available stack number on the stack.
%KERN-2-INT:
Error: Stack Port 50 has flapped 5 times w
Figure
50-22. To recover, disconnect the new unit from the stack, change
ReqTyp
CurTyp
S25N
unknown
S50N
S50N
S50V
S50V
(Figure
50-23). To recover, disconnect the new unit. Then, either:
seconds.Shutting down this st
Version
Ports
7.7.1.1
52
7.8.1.0
52
7.8.1.0
52
Stacking S-Series Switches | 1041

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents