On an E-Series Exascale platform, use the
enable VRF microcode for use with the VRF CAM-profile template, and reload the system to activate
the profile. You can set the CAM size to 40M (default) which supports both IPv4 and IPv6 or 10M
which supports only IPv4.
Note: Any physical (port or port channel) or VLAN interface assigned to a VRF uses two CAM entries
instead of one for each route and host entry.
Table 57-2
and
Table 57-3
Note: VRF is supported in single CAM cards only.
Table 57-2. IPv4-VRF CAM Profile (Single CAM card)
CAM Profile Table
L2FIB
L2ACL
IPv4FIB
IPv4ACL
IPv4Flow
EgL2ACL
EgIPv4ACL
Reserved
IPv6FIB
IPv6ACL
IPv6Flow
EgIPv6ACL
Note: When configuring the IPv6 CAM profile, the CAM tables that are carved within l2acl and ipv4Flow
tables remain at default values. For more information on the CAM and CAM profiling, refer to
"Content Addressable Memory," on page 281
Table 57-3. IPv4-v6-VRF CAM Profiles (Single CAM card)
CAM Profile Table
L2FIB
L2ACL
IPv4FIB
IPv4ACL
IPv4Flow
EgL2ACL
cam-profile
each show the required CAM settings for IPv4 and IPv6.
Allocation (K)
32K
3K
160K
2K
12K
1K
12K
2K
0K
0K
0K
0K
Allocation (K)
32K
3K
64K
1K
12K
1K
command to set the CAM size. Then select and