Table 60-4. SNMP Traps and OIDs
OID String
.1.3.6.1.4.1.6027.3.1.1.2.1.1.2
.1.3.6.1.4.1.6027.3.1.1.4.0.13
.1.3.6.1.4.1.6027.3.1.1.4.0.17
.1.3.6.1.4.1.6027.3.1.1.4.0.32
.1.3.6.1.4.1.6027.3.1.1.4.0.33
.1.3.6.1.4.1.6027.3.1.1.4.0.34
.1.3.6.1.4.1.6027.3.1.1.4.0.35
Fan Tray
.1.3.6.1.4.1.6027.3.1.1.2.2.1.2
.1.3.6.1.4.1.6027.3.1.1.4.0.36
.1.3.6.1.4.1.6027.3.1.1.4.0.21
.1.3.6.1.4.1.6027.3.1.1.4.0.16
.1.3.6.1.4.1.6027.3.1.1.4.0.20

Hardware watchdog timer

The hardware watchdog command automatically reboots an FTOS switch/router with a single
RPM that is unresponsive. This is a last resort mechanism intended to prevent a manual power
cycle.
Command
hardware watchdog
OID Name
chSysPowerSupplyOperStatus
chAlarmPowerSupplyDown
chAlarmPowerSupplyClear
chAlarmMajorPS
chAlarmMajorPSClr
chAlarmMinorPS
chAlarmMinorPSClr
chSysFanTrayOperStatus
chAlarmMinorFanBad
chAlarmMinorFanBadClear
chAlarmFanTrayDown
chAlarmFanTrayClear
Description
Enable the hardware watchdog mechanism.
Description
Each entry in the chSysPowerSupplyTable includes
a set of objects which describe the status of a
particular power supply.
Trap generated when the power supply status
changes to non-operational
Trap generated when the power supply status
changes to operational.
Trap generated when a power supply major alarm is
issued
Trap generated when a power supply major alarm is
cleared
Trap generated when a power supply minor alarm is
issued
Trap generated when a power supply minor alarm is
cleared
Each entry in the chSysFanTrayTable includes a set
of objects that describe the status of a particular fan
tray, as identified by the chSysFanTrayIndex
Trap generated when the status of one or more fans
changes to down, and generates a minor alarm
Trap generated when the minor alarm on the one or
more fans is cleared
Trap generated when all fans are down and/or when
the fan tray status changes to missing or down
Trap generated when all fans and/or the fan tray
status changes to operational