Dell Force10 C150 Configuration Manual page 1169

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

FTOS Switch Agent (SWAGT) monitors the IDP and BDP links on the line cards.
FTOS Link Monitoring task continually polls the status of the IDP and BDP links. If it finds an open link,
the system brings down the link and reports the condition via a message similar to the one shown in
Message
1.
Message 1 FTOS Link Monitoring Syslog Message Example
Mar 12 21:01:18: %RPM1-P:CP %SWMGR-1-BDP_LINK_DETECT: Backplane datapath link status for RSM0 Switch
fabric unit# 0 port# 0 => DOWN
!- Describes only the state of the port.
Mar 10 16:58:28: %RPM1-P:CP %SWMGR-1-IDP_LINK_DETECT: Internal datapath link status for Linecard#5
Switch unit# 1 port# 24 and Switch fabric unit# 3 port# 1=> DOWN
!- Describes the state of the link.
Note: These messages are not reported when a line card is reset by a user command.
If a backplane link on a line card goes down, the RPM side of the link stays up to avoid duplicate reporting.
Bringing down an IDP or BDP link causes the card to be powered-off and placed into a "card problem -
port pipe problem" state. Use the
If a single BDP link to the active RPM is down, the line card will be placed in an error state. Use the
switch links
command to view the status of the dataplane links, as shown in
Figure 60-2. show switch links backplane Command Example
FTOS#show switch links backplane
Switch fabric backplane link status:
SFM0 Links Status
LC SlotID
Port0 | Port1 | Port2 | Port3 | Port4 | Port5 | Port6 | Port7
0
not present
1
not present
2
not present
3
not present
4
not present
5
6
not present
7
not present
up - Both ends of the link are up
down - Both ends of the link are down
up / down - SFM side up and LC side down
down / up - SFM side down and LC side up
To monitor the status of a virtual SFM, use the
reports an "active" status if all CSF ASICs on the RPM initialize successfully, whether or not any line
cards are installed and the BDP links are up.
show linecard
SFM1 Links Status
up
up
up
command to view the status of a line card.
up
up/down up/down up/down up/down
show sfm
command shown in
Figure
60-2.
Figure
60-3. The system
C-Series Debugging and Diagnostics | 1169
show

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents