Dell Force10 C150 Configuration Manual page 1220

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Line card core dumps are disabled by default. To enable line card core dumps and specify the shutdown
mode:
Step
Task
1
Enable line card core dumps and
specify the shutdown mode.
Note: In the absence of port-shutdown and no-port-shutdown, the option no-port-shutdown is applied.
Once the core dump file has been created with the
from the Standby RPM flash although the space is not released. The CP kernel core dump file space cannot
be recovered by deleting the files. You must format the flash drive to recover the space.
Message 22 Internal File Transfer of Core Dump to the RPM Complete
%E48TF:0 %TME-2-TASK SUSPENDED: SAVING FAILURE RECORD COMPLETED
To locate the line card core dump file:
Step
Task
1
Change the directory to CORE_DUMP_DIR.
2
View the files in the directory.
Figure 61-12. Display the core dump directory.
FTOS#dir
Directory of flash:/CORE_DUMP_DIR
1
drwx
2
drwx
3
-r-x
5
-rwx
6
-rwx
Line card core dumps use a file naming convention of f10lp{slot#}.core.gz.
1220
|
E-Series TeraScale Debugging and Diagnostics
8192
May 12 2025 03:39:54 +00:00
32768
Jan 01 1980 00:00:00 +00:00
134217728
Jul 21 2008 22:45:12 +00:00 f10cp.kcore.gz
16384
Dec 03 2008 16:47:52 +00:00 f10cp.kcore.mini.txt
154555270
Nov 20 2008 18:57:38 +00:00 f10lp13.core.gz
Command Syntax
logging coredump linecard
port-shutdown
no-port-shutdown
[
|
logging coredump
Syntax
cd CORE_ DUMP_DIR
dir
Command Mode
{
| {
}}
EXEC Privilege
all
0-13
]
command, the file can be deleted
Command Mode
EXEC Privilege
EXEC Privilege