alarm-report
Use the
activate.Table 49-2
Task
Specify which POS/SDH alarms to report
to the remote SNMP server.
To view active alarms and defects, use the
Note: Historical data is not saved. The command input will show current information only.
Table 49-2. Alarm Definitions
Alarm
lais
lrdi
pais
plop
prdi
sd-ber
sf-ber
slof
slos
When an E-Series POS or 10GE WAN interface detects a SONET alarm, a Syslog and SNMP trap message
are generated containing information about the alarm condition.
1012
|
SONET/SDH
command to configure the SONET alarms that a POS or 10 GE WAN interface can
defines the alarms that you can enable.
Command Syntax
alarm-report
sd-ber
|
show controllers sonet
Description
Line Alarm Indication Signal
Line Remote Defect Indication
Path Alarm Indication Signal
Path loss of Pointer
Path Remote Defect Indication
LBIP BER in excess of Signal Degradation threshold
LBIP BER in excess of Signal Failure threshold
Section Loss of Frame
Section Loss of Signal
lais
lrdi
pais
plop
{
|
|
|
sf-ber
slof
slos
|
|
|
}
command in EXEC Privilege mode.
Command Mode
prdi
|
INTERFACE