Parameter Description
Parameter
severity
Default Configuration
E-mail alerting is disabled by default. When e-mail alerting is enabled, log
messages at or above severity Warning are e-mailed.
Command Mode
Global Configuration mode
User Guidelines
The logging email command with no arguments enables e-mail alerting.
Specify a severity to set the severity level of log messages that are e-mailed in
a non-urgent manner. Log messages at or above this severity level, but below
the urgent severity level, are collected together until the log time expires (the
time specified in the
single e-mail message. If you set the non-urgent severity level to the same
value as the urgent severity level, then no log messages are e-mailed non-
urgently. See the
level. The command no logging email disables all e-mail alerting.
Description
If you specify a severity level, log messages at or above the
severity level are e-mailed. The severity level may either be
specified by keyword or as an integer from 0 to 7. The accepted
keywords, and the numeric severity level each represents, are as
follows.
• emergency (0)
• alert (1)
• critical (2)
• error (3)
• warning (4)
• notice (5)
• info (6)
• debug (7)
logging email logtime
logging email urgent
command) and then e-mailed in a
command to specify the urgent severity
E-mail Alerting Commands