HP XP P9500 Manual page 153

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ40x) (continued)
Message ID
YKZ408E MSG SC=24
RC=24
Message Text
An unexpected CAJ pair status
existed during suspension of CAJ
ATTIME. (CT ID=ii, R-JNL=jj,
GENID=gg, ATTSTS=aa, SISTS=ss,
URSTS=uu, CODE=eeee,
TIME=ATTIME-suspend-time)
Explanation and Recommended Actions
Generation ID (00-FF)
aa (decimal number)
Status of ATTIME suspension (0-4)
0: No ATTIME suspend time has been set.
1: The ATTIME suspend time has been set, but
suspension has not been performed yet.
2: Suspension was performed because the ATTIME
suspend time expired.
3: Suspension was performed because the timeout
period expired, or because the Cnt Ac-J Z copy pair
was in the suspend status at the ATTIME suspend
time.
4: Suspension was performed because the system
detected a no-update journal.
ss (decimal number)
Status of ShadowImage (0-3)
0: The suspend processing has not started.
1: The suspend processing is in progress.
2: The suspend processing ended successfully.
3: The suspend processing ended abnormally.
uu (decimal number)
Status of Continuous Access Journal(0 or 1)
0: All Continuous Access Journal copy pairs were in
the DUPLEX status during the suspension.
1: During the suspension, there was a Continuous
Access Journal copy pair whose status was not
DUPLEX.
eeee (hexadecimal number)
Error information on suspend processing
0001: Suspension is not possible because the
ShadowImage copy pair status is invalid.
0002: Suspension is not possible because an error
occurred due to a problem in storage system.
ATTIME-suspend-time (GMT)
ATTIME suspend time:
YYYYMMDD-HH:MM:SS.NNNNNN
YYYY: Year
MM: Month
DD: Day
HH: Hour
MM: Minute
SS.NNNNNN: Second
The status of the Cnt Ac-J Z copy pair was invalid
while the suspend processing using the CAJ ATTIME
suspend function was being performed.
Check the status of the Cnt Ac-J Z copy pair, and
remove the problem. After that, use the YKSUSPND
command to cancel the ATTIME suspend time, and
then acquire the backup again. See
Messages Output to SYSTSPRT" (page 159)
"Multi-line
for details.
List of Messages 153