Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKA0x) (continued)
Message ID
YKB204W TSO
YKC000T TSO
RC=48
YKC001E MSG
SC=48 RC=48
YKC001E TSO
RC=48
YKC001E MSG
SC=48 RC=48
YKC001E MSG
SC=48 RC=48
Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKC0x)
Message ID
YKC000T TSO
RC=48
YKC001E MSG
SC=48 RC=48
YKC001E TSO
RC=48
YKC001E MSG
SC=48 RC=48
YKC001E MSG
SC=48 RC=48
YKC002E MSG
SC=48 RC=48
YKC002E TSO
RC=48
32
Messages
Message Text
A dynamic configuration
change was detected.
DEVN=device-number
Supplied parameters invalid
No controller ARRAYS()
supplied
No message MSG() supplied
No results STEM() supplied
No starting FROM() supplied
Message Text
Supplied parameters invalid
No controller ARRAYS()
supplied
No message MSG() supplied
No results STEM() supplied
No starting FROM() supplied
Controller ARRAYS(stem) does
not include trailing "."
Messages MSG(stem) does
not include trailing "."
Explanation and Recommended Actions
CCA#
The command control address number of the
detected undefined volume
A dynamic change was detected in an I/O configuration definition
while the YKP2B command was executing with CHECK specified
for the HS parameter.
Check the status of the device targeted by the YKP2B command,
correct any errors in the configuration or execution conditions, and
then re-execute the command.
device-number
Device number being processed when a dynamic
change was detected in an I/O configuration
definition
Invalid parameters are specified.
For details, see the reason code in the YKC099I message displayed
after this message. For reason codes, see IKJPARS in the TSO/E
Programming Services.
Nothing is assigned to the ARRAYS parameter.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the STEM parameter.
Nothing is assigned to the FROM parameter.
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKC099I message displayed
after this message. For reason codes, see IKJPARS in the TSO/E
Programming Services.
Nothing is assigned to the ARRAYS parameter.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the STEM parameter.
Nothing is assigned to the FROM parameter.
The last character of the ARRAYS parameter is not a period.
stem
Stem name assigned to the ARRAYS parameter
The last character of the MSG parameter is not a period.