HP XP P9500 Manual page 190

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 55 Details of Error Codes 50xx – 6Axx (continued)
Error
Error Details
Code
The corresponding volume is
online.
The corresponding volume is
being used by another program
product such as BC Z, Cnt Ac-S
Z, TCA, Cnt Ac-J Z or
Compatible FlashCopy.
The emulation type of the
corresponding volume is
3390–V.
A command device cannot be
64FC
redefined because the APID that
was already defined does not
match the APID you attempted to
define.
The command device cannot be
64FD
defined because a command
device with the same APID has
been defined for another device.
A command device cannot be
64FF
defined because the APID specified
by the parameter does not match
the APID defined for the command
device.
The host command parameter is
69E4
invalid.
A path cannot be deleted because
69E6
there is an invalid parameter.
The command cannot be executed
69E7
because the specified volume does
not exist.
The command cannot be executed
69E8
because the specified volume is
blocked.
The command cannot be executed.
69E9
The reason might be one of the
following:
The corresponding volume is in
the SIMPLEX status.
The corresponding volume is not
part of a TCA copy pair.
The corresponding volume is not
a P-VOL.
A path cannot be established
69F2
because there is an invalid
parameter.
The storage system serial
number is incorrect.
The SSID is incorrect.
The CU number is not
supported.
190 Storage System Sense Byte Information
Type of Error
BC Z
Cnt Ac-S Z
TCA
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Output
Not output
Cnt Ac-J Z
CMD
PATH
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Others
Output
Not
output
Output
Output
Not
output

Advertisement