Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM0x) (continued)
Message ID
Message Text
Z/CA/TCA Copy Group
definition.
YKM042E ISPF
This Consistency Group ID
(C/T ID,sub C/T ID) is
already defined. Choose a
different ID.
YKM043E ISPF
A Mirror ID is required for
CAJ Copy Group definition.
YKM044E ISPF
This Path Set ID is already
defined.
YKM045E ISPF
Physical path (priport secport)
is already defined in this
logical path.
YKM046E ISPF
The end CU/CCA value must
not be lower than the start
CU/CCA.
YKM047E ISPF
Processing to insert or edit a
storage system was denied
because the storage system
has already been discovered
by the selected DADID.
YKM048E ISPF
You cannot perform a device
scan because in the Set
Defaults panel, a remote DAD
ID or Non Gen'ed DAD ID
was specified as the local
DAD ID.
YKM049E ISPF
This storage system can't be
selected because it hasn't
been scanned yet.
YKM050E MSG
Invalid Copy Group attribute
SC=36 RC=48
name
(attribute-value)
YKM056E MSG
NOCOPY option invalid for
SC=36 RC=48
BC Z Copy Group
YKM058E MSG
Some pairs in this group do
SC=36 RC=48
not support TCA services
Explanation and Recommended Actions
This C/T group ID is already defined. Choose a different ID.
For the Cnt Ac-J Z copy group definition, you need to specify a
mirror ID.
This path set ID is already defined.
The physical path is already defined as a logical path.
priport
The primary port you specified
secport
The secondary port you specified
The end CU/command control address value is lower than the
start CU/command control address value.
A storage system cannot be inserted into, or edited in a route
because the storage system has already been scanned via the
specified device address domain ID.
Correct the specified device address domain ID and serial number
of the storage system.
Devices cannot be scanned because in the Set Defaults panel,
the remote device address domain ID or Non Gen'ed device
address domain ID has been specified as the local device address
domain ID.
The storage system cannot be selected because it has not yet
been scanned.
The specified copy group attribute value is invalid for this
command.
Correct the value and then re-execute the command.
name
REXX variable name
attribute-value
REXX variable value
The YKMAKE command with the NOCOPY parameter specified
was executed on an BC Z copy group. This parameter is invalid
on BC Z copy groups.
Re-execute the YKMAKE command without specifying the NOCOPY
parameter.
One or more devices in the HP XP 256 Disk Array storage system
do not support TCA copy groups.