Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ21x – YKZ24x) (continued)
Message ID
YKZ226E MSG SC=36
#
RC=48
YKZ227E MSG SC=36
#
RC=36
YKZ228E MSG SC=36
#
RC=36
(pair-index)
YKZ229I MSG SC=0
RC=0
YKZ230W MSG SC=4
RC=4 (pair-index)
126 Messages
Message Text
stemTCA_MAP=TRK not supported
by some group pairs
stemTCA_FLOWCONTROL=N not
supported by some group pairs.
Invalid pair attribute name = value
The time specified with ATTIME has
past. The specification of ATTIME is
ignored.
Management for the relevant volume
was skipped. DEVN
device#(SN,CU#,CCA#)
Explanation and Recommended Actions
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
For the specified model, TRK cannot be specified for
TCA_MAP in the TCA options.
Correct the contents of the configuration file.
stem
Stem name
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Some copy pairs in this group do not support
TCA_FLOWCONTROL=N.
Correct the configuration file, and then re-execute
the YKLOAD command.
stem
Stem name
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
The value of the REXX variable is invalid.
Check that the value is specified according to the
following rules:
The command control address must consist of 2
digits.
The control unit number must consist of 2 digits.
The SSID must consist of 4 digits.
The storage system serial number must consist of
5 digits.
The device number must consist of up to 4 digits.
name
REXX variable name
value
Value
pair-index
See the pair index description in
the explanation of the YKE003E
message.
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
The time assigned to the ATTIME parameter has
elapsed. Processing will continue, ignoring the
specification of the ATTIME parameter.
Processing for the volume was skipped because the
status of the volume did not allow this command to
be executed. If 0 is displayed in the location that
indicates the copy pair corresponding to the
pair-index, multiple volumes within the copy group
have been skipped.