Table 58 Details of Error Codes 8Fxx
Error
Error Details
Code
A Cnt Ac-J Z copy pair cannot be
8F00
made because the specified volume
is an external volume.
A Cnt Ac-J Z copy pair cannot be
8F10
made because the specified volume
has been made as a copy pair for
BC Z or FlashCopy and cannot be
used for this combination.
A Cnt Ac-J Z copy pair cannot be
8F14
made because the specified volume
is a Reserve volume.
A Cnt Ac-J Z copy pair cannot be
8F17
made because the specified volume
is online.
A Cnt Ac-J Z copy pair cannot be
8F18
made because the specified volume
has been made as a copy pair for
another program product.
A Cnt Ac-J Z copy pair cannot be
8F19
made because the emulation type of
the specified volume cannot be used
in Cnt Ac-J Z.
A Cnt Ac-J Z copy pair cannot be
8F1B
made because the specified P-VOL
is not in the SIMPLEX status.
A Cnt Ac-J Z copy pair cannot be
8F1C
resynchronized because the
specified P-VOL is not in the suspend
status.
A Cnt Ac-J Z copy pair cannot be
8F1E
made because the cache or SM is
being recovered.
A Cnt Ac-J Z copy pair cannot be
8F1F
made because the cache or SM is
blocked.
A Cnt Ac-J Z copy pair cannot be
8F21
made. The reason might be one of
the following:
The configurations cannot be
combined because the specified
volume is the P-VOL of a Cnt Ac-S
Z or TCA copy pair, or the
specified volume is part of a BC
Z copy pair.
0 (zero) is specified as the mirror
ID in the Cnt Ac-S Z or TCA
configurations.
Alternatively, a Cnt Ac-J Z copy
pair cannot be resynchronized
because the configuration does
not allow the status to be
changed.
204 Storage System Sense Byte Information
Type of Error
BC Z
Cnt Ac-S Z
TCA
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Cnt Ac-J Z
CMD
PATH
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Others