Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ28x) (continued)
Message ID
YKZ286E MSG SC=36
RC=36 (index)
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ29x)
Message ID
YKZ290E MSG SC=48
RC=48
YKZ291I CON SC=0
RC=0
YKZ292I CON SC=0
RC=0
Message Text
YKQRYPTH command cannot be
executed if the volume on the CU
type path has not been scanned.
Message Text
FROMCU() exceeds number of CU
that storage systems supported.
The log dataset is full. (DSN=ddd,
cp=xxx:yyy)
The log dataset was switched.
(from=YKLOGmm, to=YKLOGnn,
job=jjj, cp=xxx:yyy)
Explanation and Recommended Actions
To execute one of these commands against a logical
path, correct the configuration file and then execute
the YKLOAD command.
index
Index number of the logical path
without a port element
When the YKQRYPTH command is executed on a
storage system that has not been directly connected
to the host for the path set of an inter-control unit
logical path, the volume belonging to the originally
established inter-control unit of the inter-control unit
logical path must have been scanned at least once.
Make sure that the volume belonging to the targeted
control unit has been scanned at least once, and the
control unit and command control address defined
for the path set are correct. If the command control
address is not defined for the path set, from the Edit
Logical Path Definition panel, specify the command
control address of the volume scanned in the target
control unit for path control.
index
Index number of the logical path
that cannot be executed
Explanation and Recommended Actions
The FROMCU has exceeded the maximum number of
CUs that are supported by storage systems.
Specify the maximum supported number of CUs or
less.
The log dataset is full.
ddd
Name of the log dataset that
became full
If a log dataset name cannot be
collected, * is displayed.
xxx (decimal number)
Command code for the command
that was executing when the log
dataset became full
See the description for the
command code in the YKZ201E
message.
yyy (string)
Maintenance information
The log dataset was switched.
YKLOGmm