Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
YKJ099I TSO RC=0
YKJ100E TSO
RC=32
YKJ101I TSO RC=4
YKJ102E TSO
RC=32
YKJ150E TSO
RC=40
YKJ151E TSO
RC=40
50
Messages
Message Text
cmd command completed.
RC= return-code
Error occurred during
reading/writing
configuration file: file
No copy pair is defined in
specified Copy Group
definition: file
name is not specified in
Copy Group definition
specified by BASEGROUP.
Error reported during file
input/output. EXECIO RC=
n: dd-name
File format is invalid:
DSORG= XX. DSORG must
be PS: dd-name
Explanation and Recommended Actions
If no additional information is available, a space
is displayed.
The error messages message-text, message-value, and
message-severity are displayed in the TSO/E terminal. Depending
on the length of the error messages, they might extend over several
lines.
The command identified by cmd has ended with a return code
identified by return-code.
cmd
Command name
An error occurred while reading data from or writing data to the
configuration file.
file
Name of the configuration file where the error
was detected
No copy pair is defined for the specified copy group. No data
was written in the CSV file.
file
Name of the specified copy group definition file
The copy group definition file specified by the BASEGROUP
parameter does not include the element identified by name.
Set the necessary elements in the copy group definition file that is
to be used as the base, and then retry.
name
Name of an element in the copy group definition
file
Processing ended due to the EXECIO TSO/E REXX command
failure (return code = n). For details, see the TSO/E REXX User's
Guide.
The probable causes are as follows:
No CSV file is assigned to the DD name required for the
command.
The dataset format of the CSV file is not supported.
dd-name
DD name of the CSV file where the error was
detected
The dataset format of the CSV file identified by dd-name is invalid.
Delete the current CSV file and create a CSV file that is in the correct
dataset format.
For details about the CSV file dataset format, see the HP P9000
for Business Continuity Manager Software Reference Guide.
XX
DSORG of the CSV file where the error was
detected
dd-name