Table 24 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKU0x) (continued)
Message ID
YKU058E MSG SC=36
RC=48
YKU099I TSO
Table 25 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKV0x)
Message ID
YKV000T TSO RC=48
YKV001E TSO RC=48
YKV001E MSG SC=48
RC=48
YKV002E MSG SC=48
RC=48
YKV002E MSG SC=48
YKV002E TSO RC=48
YKV008E MSG SC=48
YKV010E TSO RC=40
94
Messages
Message Text
Some pairs in this group do not
support TCA services.
YKSUSPND command return
code=nnnn, reason code=rrrr
Message Text
Supplied parameters invalid
No message MSG() supplied
No results STEM() supplied
Copy Group STEM(stem) does
not include trailing "."
DEVN() value invalid
Messages MSG(stem) does not
include trailing "."
DEVN() not valid hex
REXX failure return code=nnnn
starting with variable name
Explanation and Recommended Actions
parameter specified. These parameters are invalid on
Cnt Ac-J Z copy groups.
Re-execute the YKSUSPND command without specifying
the ATTIME or CANCEL parameter.
One or more devices in the HP XP 256 Disk Array
storage system do not support TCA copy groups.
Check that the command can be executed on this copy
group, and then re-execute the command.
The YKSUSPND command terminated with the return
code nnnn and the reason code rrrr.
This message is always displayed to indicate the return
code and the reason code.
nnnn
Maximum among the severity codes
returned during command execution
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKV099I
message that will appear after this message. For reason
codes, see IKJPARS in the TSO/E Programming
Services.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the STEM parameter.
The last character of the STEM parameter is not a
period.
stem
Stem name assigned to the STEM
parameter
The value assigned to the DEVN parameter is invalid.
The last character of the MSG parameter is not a period.
stem
Stem name assigned to the MSG
parameter
The value specified in the DEVN parameter is not in
hexadecimal format.
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the
TSO/E Programming Services.
nnnn
Error code returned upon REXX
access

Advertisement