Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ3x) (continued)
Message ID
YKZ301E CON RC=128
YKZ310I CON
YKZ31 1I CON
YKZ320E TSO
YKZ321E TSO
YKZ322E TSO
YKZ330E TSO RC=64
148 Messages
Message Text
The task is not authorized to execute
the request.
hh:mm:ss command
hh:mm:ss command RC=rc
Supplied parameters invalid.
Time value is invalid.
Specify SEC and MIN parm
exclusively.
command detected the rexx-service
service error. (return code=r[, reason
code=n]).
Explanation and Recommended Actions
For details about registering a user SVC, see the HP
P9000 for Business Continuity Manager Software
Installation Guide.
The task is not authorized to execute a CLI command.
The program will terminate abnormally with user
completion code 128.
For details about how to set CLI command execution
permissions, see the HP P9000 for Business
Continuity Manager Software Reference Guide.
This log data indicates that a CLI command has been
issued.
hh:mm:ss
Time the CLI command was issued
(local time)
command
Issued CLI command name and
its parameters
A maximum of 109 characters
can be output. If 109 is
exceeded, the remainder are
discarded.
This log data indicates the result of a CLI command
execution.
hh:mm:ss
Time the CLI command was issued
(local time)
command
Issued CLI command name
rc
Return code for the CLI command
For details, see the command
descriptions in the HP P9000 for
Business Continuity Manager
Software Reference Guide.
An error was detected during parameter analysis.
The specified time value is invalid.
The SEC and MIN parameters cannot be specified
at the same time.
An error was detected in the REXX service.
command
Issued CLI command name.
rexx-service
Name of the REXX service where
an error was detected.
r (decimal number)
Return code from the REXX
service.