Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM0x) (continued)
Message ID
YKM099I TSO
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKM1x – YKM5x)
Message ID
YKM103E MSG
SC=48
YKM500E ISPF
YKM501E ISPF
YKM502E ISPF
YKM503E ISPF
YKM504E ISPF
YKM505E ISPF
YKM506E ISPF
YKM507E ISPF
72
Messages
Message Text
YKMAKE command return
code=nnnn, reason code=rrrr
Message Text
The parameter combination is
invalid
You cannot perform a remote
scan if the specified DAD ID
matches a local or Non
Gen'ed DAD ID or if the
loaded HDA file is not for
remote scan or if the Preset
RouteListID, in the Set Defaults
panel, is not enabled.
You cannot edit the device
number for a volume that was
not found by remote scan or
NG scan.
You cannot exit until all
discovered devices are
assigned dummy devn.
The number of connections of
inter-DKC paths exceeds the
maximum number of
connections that is allowed
within the same storage
system.
The number of connections of
inter-DKC paths of the same
PathID exceeds the maximum
number of connections that is
allowed within the same
storage system.
This inter-DKC path is already
defined in another logical
path.
You cannot define inter-DKC
path with this interface version.
The number of connections of
inter-CU paths exceeds the
maximum number of
Explanation and Recommended Actions
Check that the command can be executed on this copy group,
and then re-execute the command.
The YKMAKE command terminated with the return code nnnn and
the reason code rrrr.
This message is always displayed to indicate the return code and
the reason code.
nnnn
Maximum among the severity codes returned
during command execution
Explanation and Recommended Actions
The parameter combination is invalid.
A remote scan cannot be performed in the following cases:
The specified device address domain ID is equivalent to the
local device address domain ID or a Non Gen'ed device
address domain ID.
When the HDA file is not a file used for a remote scan.
When the Preset RouteListID set in the Set Defaults panel is
not valid.
The device number cannot be edited because the volume was
not found by a remote scan or a NG scan. For details about
the NG scan, see the HP P9000 for Business Continuity
Manager Software Reference Guide.
The exit operation cannot be performed until a device number
is assigned to all discovered devices.
The number of connections of inter-DKC paths exceeded the
maximum that is allowed within the same storage system.
The number of connections of inter-DKC paths of the same PathID
exceeded the maximum that is allowed within the same storage
system.
This inter-DKC path is already defined in another logical path.
In this interface version, the user cannot define inter-DKC paths.
The number of connections of inter-CU paths exceeded the
maximum that is allowed within the same CU.