<cgmonstat>: Copy group monitoring status (ACTIVE or INACTIVE)
<cgsastat>: Copy group startup status to be checked for starting BCM Monitor
<cgsaact>: Startup action executed if the copy pair status for starting BCM Monitor is different
from the specified startup status
<cgsaopt>: Option information of the CGSTARTUPSTATUS parameter
<status> <action><err-action>: Status, action, and error action for the copy group
specified in STATUS and ACTION. These parameters appear a specified number of times.

User Completion Codes

Table 46 (page 163)
Table 46 User Completion Codes
Completion Code
U0003
U0128
U1009

Identifying the Volume to Be Processed

The volume to be processed is determined by the copy group number and copy pair number output
in a message as follows:

Identifying the Volume Serial Number from the REXX Script

Display the following STEM variable.
stem-name.CopyGroup..copy-group-number..Pair..copy-pair-number.Volser
provides details about the user completion codes.
Explanation
There is a problem with the issued CCW.
The version of the registered user SVC routine might be old. Check whether the latest
user SVC routine is registered by performing one of the following operations:
Using a CLI command:
Execute the YKINSCHK command, and check that OK is displayed for User SVC
Routine.
From the ISPF panel:
From the Installation Verification Summary panel, check that OK is displayed for
User SVC Routine.
The user does not have the permission to execute CLI commands.
If a reason code exists, it is displayed in the following format:
XXYYZZZZ:
XX: Lower 1 byte of SAF RC of the RACROUTE macro
YY: Lower 1 byte of RACF RC of the RACROUTE macro
ZZZZ: Lower 2 bytes of RACF Reason Code of the RACROUTE macro
If the reason code is 00000040:
The user who attempted to execute the command has been granted
only the view permission for the STGADMIN.YKA.BCM.YKQUERY
profile. Therefore, the user cannot execute CLI commands to
operate copy pairs, paths, and command devices.
If the reason code is other than the above:
The information returned from the RACROUTE REQUEST=AUTH
macro is displayed. For details, see the Security Server RACROUTE
Macro Reference.
An attempt was made to call a module that cannot be executed in Business Continuity
Manager. There might be a problem in the LINKLIB library settings. Specify the
Business Continuity Manager installation dataset for the LINKLIB library.