Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
YKG298E MSG
TSO SC=44 RC=44
(detailed-info)
YKH001I TSO
46
Messages
Message Text
YKGETHDA encountered an
unexpected error.
YKH2B completed.
RC=return-code
Explanation and Recommended Actions
An unexpected error has occurred.
This error might have occurred with another error.
If another error message was output at the same time as this one,
follow the instructions in that message to fix the corresponding
problem.
If no other error message was output, collect the following materials
and contact your service representative:
The script from which this command was executed (not necessary
if this command was executed from the ISPF panel).
The ISPF log (not necessary if this command was executed from
a script).
The definition files operated on from the script or ISPF panel (the
copy group definition file, disk configuration definition file,
command device definition file and route list definition file).
detailed-info
Detailed information to assist service representative in resolving the
problem
The YKH2B command terminated.
return-code
The return code of the YKH2B command
0: The command ended successfully. One or
more copy group definition files were created.
4: Indicates that one of the following occurred:
The command ended successfully. No copy
pair was detected within the range of the
specified device numbers.
A copy group definition file was created, but
volume information not defined in the disk
configuration definition file for the site
specified in the DAD parameter was detected
among copy pairs within the range specified
in the DEVN parameter.
A copy group definition file was created, but
a change was detected in the I/O
configuration when the YKH2B command was
executed without specifying the HS parameter
or the YKH2B command was executed by
specifying HS(CHECK).
A copy group definition file was created, but
a storage system that does not support 2DC
configuration with HyperSwap and Cnt Ac-J
Z was detected.
8: An I/O error occurred in a volume within the
scan range. Copy group definition files were
created for the volumes that were successfully
detected.
44: The processing was cancelled due to an
error. The copy group definition file was not
created.
48: The command ended due to an invalid
parameter.