HP XP P9500 Manual page 9

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Message ID
Message Text
YK8017E CON
Invalid command:
command-name.
YK8018E CON
Operand is incorrect:
command-name.
YK8019E CON
The number of commands of
execution waiting exceed
the upper limit:
command-name.
YK8020I CON
nn:
command-name[parameter].
YK8021I CON
Execution waiting command
none.
YK8022I CON
The state of sleep was
released.
YK8023W CON
The WAKEUP command was
not executed because it is
not in a sleep status.
YK8024E CON
Insufficient space available:
maintenance-information.
YK8025E CON
IRXJCL module error:
return-code.
Explanation and Recommended Actions
There is an error in the command-name command.
Make sure that the entered command is valid.
There is an error in an operand of the command-name command.
Correct the operand, and then re-enter the command.
An attempt to execute the command identified by command-name
failed because the number of commands waiting to be executed
has reached the upper limit.
Wait until all the waiting commands are finished executing, and
then re-execute the command.
Information is displayed for the command waiting to be executed.
nn
Number assigned to the waiting command
command-name
Name of the waiting command
The full name of the command is displayed, even
if the abbreviated name of the command was
entered.
parameter
Parameter specified in the waiting command
The full name of the parameter is displayed, even
if the abbreviated name of the parameter was
specified. If an omittable parameter was omitted,
the default value is displayed.
There is no command waiting to be executed.
BCM Monitor returned from the sleep state.
The WAKEUP command cannot be executed because BCM Monitor
is not in the sleep state.
An attempt to allocate space to BCM Monitor failed. BCM Monitor
will stop.
Increase the region size, and then restart BCM Monitor.
maintenance-information
Detailed information to assist in analyzing the
error
The IRXJCL routine returned an error with the return code identified
by return-code. BCM Monitor will stop.
Check the return code. If the code is 20, the SYSEXEC DD
statement might be invalid in the cataloged procedure for startup
for BCM Monitor.
Check the JCL, and then re-execute IRXJCL.
List of Messages
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents