Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ27x) (continued)
Message ID
YKZ273E MSG SC=36
RC=36
YKZ274E MSG SC=36
RC=36 (index1, index2,
index3)
YKZ274E MSG SC=36
RC=36 (index1, index2,
index3)
YKZ275E MSG SC=36
RC=36
YKZ276E MSG SC=36
RC=36
140 Messages
Message Text
No path to be operated exist within
the range specified by the supplied
parameter.
Duplicate ports exist in FORWARD.
Duplicate ports exist in REVERSE.
Necessary Routelist or DEVN
information is not found.
Some of the arrays do not support
storage system type paths.
Explanation and Recommended Actions
No paths to be operated exist within the range
specified by the parameter.
Check the parameters specified during command
execution, the path set name specified during the
YKLOAD command execution, and the attributes of
the path set (path type, shared attributes, storage
system serial numbers, and CU numbers).
In the logical path definition for FORWARD index1,
the index2 and index3 port numbers are duplicated.
Delete one of the definitions or make sure that the
duplicated port numbers are correct, and then
re-execute the command.
index1
Index number of the duplicated
logical path
index2
Index number of one of the
duplicated ports
index3
Index number of the other
duplicated port
In the logical path definition for REVERSE index1,
the index2 and index3 port numbers are duplicated.
Delete one of the definitions or make sure that the
duplicated port numbers are correct, and then
re-execute the command.
index1
Index number of the duplicated
logical path
index2
Index number of one of the
duplicated ports
index3
Index number of the other
duplicated port
The route list or device number information, required
for processing to continue, is missing.
Correct the value assigned to the ROUTE, DAD or
PATH parameter passed to the YKLOAD command.
Make sure that the specified volume has been
scanned, because this message is output when the
volume for CU and CCA specified in the path set
definition file has not been scanned.
A storage system using a path-controlled device or
Remote Disk Controller control contains an IFType,
which is not supported for disc controller-type path
control.
In the configuration file, make sure that the storage
system is controllable (that the first two digits of the

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents