HP XP P9500 Manual page 52

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
YKJ202I TSO RC=4
YKJ203E TSO
RC=32
YKJ204E TSO
RC=32
YKJ205E TSO
RC=32
YKJ206E TSO
RC=32
YKJ207W TSO
RC=8
52
Messages
Message Text
No copy pair is defined in
specified Pair information
CSV file.
The number of items
specified for a line in Pair
information CSV file is
invalid: dd-name: rec#
Primary volume is not
specified in Pair information
CSV file: dd-name: rec#
Secondary volume is not
specified in Pair information
CSV file: dd-name: rec#
The specified volume does
not exist in the disk
configuration definition file:
dd-name: rec#: device
Inconsistencies exist among
the values used to specify
the primary volume:
dd-name: rec#
Explanation and Recommended Actions
No copy pair is defined in the pair information CSV file. No data
was written in the copy group definition file.
The number of items specified on one line of the pair information
CSV file is incorrect.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
No P-VOL is specified in the pair information CSV file.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
No S-VOL is specified in the pair information CSV file.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
The specified volume does not exist in the disk configuration
definition file.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected device
One of the following is displayed. If both are specified, the device
number is displayed.
Device number
Storage system serial number, CU number, and command control
address number
The display format is
storage-system-serial-number:CU-number:CCA-number.
The P-VOL specified with the device number differs from the P-VOL
specified with the storage system serial number, CU number, and
command control address number.
Although the copy group definition file was created, the settings
therein might contain an error.
dd-name
DD name of the CSV file where the error was
detected

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents