Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKQ0x)
Message ID
Message Text
YKQ000T TSO RC=48
Supplied parameters invalid
YKQ001E TSO RC=48
No message MSG() supplied
YKQ001E MSG
No results STEM() supplied
SC=48 RC=48
YKQ002E MSG
Copy Group STEM(stem) does
SC=48 RC=48
not include trailing "."
YKQ002E MSG
DEVN() value invalid
SC=48
YKQ002E TSO RC=48
Messages MSG(stem) does not
include trailing "."
YKQ003E MSG
Parameters combination is
SC=48
invalid
YKQ008E MSG
DEVN() not valid hex
SC=48
YKQ010E TSO RC=40
REXX failure return code=nnnn
starting with variable name
YKQ018E MSG
BC Z PAIR deficiency. DEVN
SC=16 RC=16
device#(SN,CU#,CCA#)
(pair-index)
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKQ099I message
that will appear after this message. For reason codes, see
IKJPARS in the TSO/E Programming Services.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the STEM parameter.
The last character of the STEM parameter is not a period.
stem
Stem name assigned to the STEM
parameter
The value assigned to the DEVN parameter is invalid.
The last character of the MSG parameter is not a period.
stem
Stem name assigned to the MSG
parameter
The parameter combination is invalid.
The value specified in the DEVN parameter is not in
hexadecimal format.
Access to the REXX variable indicated by name failed.
For details about the return code, see IKJCT441 in the
TSO/E Programming Services.
nnnn
Error code for REXX access
In an BC Z copy group, the volume in the target copy pair
has already been paired with three volumes other than the
pairing volume specified in the copy group definition.
Review the applicable copy pair definition in the copy group
definition.
device#
Device number
If the device cannot be identified, ****
is displayed.
SN
Storage system serial number
If the device cannot be identified,
************ is displayed.
CU#
Control unit number
If the device cannot be identified, ** is
displayed.
List of Messages