Delta Electronics PCI-DMC-A01 Programming Manual page 360

High-speed pci 12-axis motion control card
Hide thumbs Also See for PCI-DMC-A01:
Table of Contents

Advertisement

Chapter 25 Remote Module Control API | PCI-DMC-A01 / PCI-DMC-B01
25.5 _DMC_01_set_rm_output_value_error_handle
 FORMAT
I16 PASCAL _DMC_01_set_rm_output_value_error_handle(U16 CardNo, U16 NodeID,
U16 SlotID,U16 port,U16 value)
 Purpose
Sets the output value returned when remote I/O module encounters an error.
 Parameters
Name
Data Type
CardNo
NodeID
SlotID
port
value
 Example
U16 CardNo=0;
U16 NodeID=1;
U16 SlotID=0;
U16 Port=0;
U16 Value=1;
I16 status = _DMC_01_set_rm_output_value_error_handle(CardNo, NodeID, SlotID, port,
Value);
25-6
Unit
U16
Number Unit
U16
Number Unit
U16
Number Unit
U16
Selection
U16
Selection
Description
CardNo is between 0~15
Node ID
Slot ID
0: Port 0
1: Port 1
2: Port 2
3: Port 3
0: When an error occurs, the error output value
will be reset to 0
1: When an error occurs, retain the value until
system is powered off
Revised March, 2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pci-dmc-b01

Table of Contents