Delta Electronics PCI-DMC-A01 Programming Manual page 204

High-speed pci 12-axis motion control card
Hide thumbs Also See for PCI-DMC-A01:
Table of Contents

Advertisement

Chapter 9 Point to Point Motion Control Packet Protocol API | PCI-DMC-A01 / PCI-DMC-B01
9.3
_DMC_01_start_sdo_driver_a_move
 FORMAT
I16 PASCAL _DMC_01_start_sdo_driver_a_move (I16 CardNo, U16 NodeID, U16 SlotID,
I32 Position)
 Purpose
Starts absolute motion displacement.
 Parameters
Name
Data Type
CardNo
NodeID
SlotID
Position
 Example
U16 CardNo=0;
U16 NodeID =1;
U16 SlotID = 0; //If Slot ID is set to 0, then the Slave is a servo drive
I32 Position =10000000;
I16 status= _DMC_01_start_sdo_driver_a_move (CardNo, NodeID, SlotID, Position);
9-4
U16
Number Unit
U16
Number Unit
U16
Number Unit
I32
Number of pulses
Unit
CardNo is between 0~15
Node ID
Slot ID
Absolute motion position
Description
Revised March, 2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pci-dmc-b01

Table of Contents