Chapter 9 Point to Point Motion Control Packet Protocol API | PCI-DMC-A01 / PCI-DMC-B01
9.2
_DMC_01_start_sdo_driver_r_move
FORMAT
I16 PASCAL _DMC_01_start_sdo_driver_r_move (U16 CardNo, U16 NodeID, U16 SlotID,
I32 Distance)
Purpose
Starts relative motion displacement.
Parameters
Name
Data Type
CardNo
NodeID
SlotID
Distance
Example
U16 CardNo=0;
U16 NodeID =1;
U16 SlotID = 0; //If Slot ID is set to 0, then the Slave is a servo drive
I32 Distance =10000000;
I16 status= _DMC_01_start_sdo_driver_r_move (CardNo, NodeID, SlotID, Distance);
Revised March, 2012
Unit
U16
Number Unit
U16
Number Unit
U16
Number Unit
Number of
I32
pulses
Description
CardNo is between 0~15
Node ID
Slot ID
Relative motion distance
9-3