Ctp Card Events (400 Through 499 - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

CTP Card Events (400 through 499)

Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as indicated
by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure is
indicated, replace the power supply assembly. Perform the data collection procedure
and return the Zip disk to Hewlett-Packard support personnel.
Event Data:
Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply
assembly.
Byte 1 = FRU slot number.
Distribution:
Switch
EWS
Event
Log
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code 411), or be user-initiated. Event
data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution:
Switch
EWS
Event
Log
edge switch 2/24 service manual
Event Code: 400
HAFM Server
System
Event
Error
Log
LED
Event Code: 410
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes