Ctp Card Events (400 Through 499) - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw 05.01.00 and sw 07.01.00 edge switch 2/24 service manual
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

CTP Card Events (400 through 499)

Table 67: Event Code 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as
indicated by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure
is indicated, replace the power supply assembly. Perform the data collection
procedure and return the Zip disk to Hewlett-Packard support personnel.
Event Data:
Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply
assembly.
Byte 1 = FRU slot number.
Distribution:
Switch
EWS
Event
Log
Table 68: Event Code 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code 411), or be user-initiated.
Event data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM Server
System
Event
Error
Log
LED
HAFM Server
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
253

Advertisement

Table of Contents
loading

Table of Contents