IBM BladeCenter JS21 Types 8844 Service Manual page 93

Problem determination and service guide
Hide thumbs Also See for BladeCenter JS21 Types 8844:
Table of Contents

Advertisement

SRN
FFC
652-666
304
652-669
2CD
652-66A
2CE
652-66B
2CC
652-731
2C8
652-732
2C8
652-733
2C8
292
652-734
2C8
292
652-735
2D2
292
652-736
2D2
292
652-770
2C8
292
652-771
2C8
292
652-772
2D2
292
652-773
227
652-88x
652-89x
Description and action
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred G maintenance. Go to "Performing the checkout procedure" on
page 106.
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: intermediate or system bus address parity
error. Action: Schedule deferred maintenance. Go to "Performing the checkout
procedure" on page 106.
A non-critical error has been detected: intermediate or system bus data parity error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate or system bus address parity
error. Action: Schedule deferred maintenance. Go to "Performing the checkout
procedure" on page 106.
A non-critical error has been detected: intermediate or system bus data parity error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate or system bus time-out error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate or system bus time-out error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate system bus address parity error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate or system bus data parity error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate or system bus time-out error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: intermediate or system bus data parity error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
The CEC or SPCN reported a non-critical error. Action: Schedule deferred
maintenance. Refer to the entry MAP in this system unit's system service guide, with
the 8-digit error and location codes, for the necessary repair action. If the 8-digit error
and location codes were NOT reported, then run diagnostics in problem determination
mode and record and report the 8-digit error and location codes for this SRN.
The CEC or SPCN reported a non-critical error. Action: Schedule deferred
maintenance. Refer to the entry MAP in this system unit's system service guide, with
the 8-digit error and location codes, for the necessary repair action. If the 8-digit error
and location codes were NOT reported, then run diagnostics in problem determination
mode and record and report the 8-digit error and location codes for this SRN.
77
Chapter 2. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents