IBM BladeCenter JS21 Types 8844 Service Manual page 91

Problem determination and service guide
Hide thumbs Also See for BladeCenter JS21 Types 8844:
Table of Contents

Advertisement

SRN
FFC
651-780
2C7
214
651-781
2C7
214
651-784
302
214
651-785
303
214
651-786
304
214
651-789
2CD
214
651-78A
2CE
214
651-78B
2CC
214
651-809
651-810
2E2
651-811
2E2
651-813
651-818
651-820
2E1
651-821
2E1
651-822
2E1
651-831
2E2
Description and action
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Power fault warning due to unspecified cause. Action: Go to "Performing the checkout
procedure" on page 106.
Over-voltage condition was detected. Action: Shut the system down and do the
following before replacing any FRUs:
1. Visually inspect the power cables and reseat the connectors.
2. Run the following command diag -Avd sysplanar0. When the Resource Repair
Action menu displays, select sysplanar0.
Under voltage condition was detected Action: Shut the system down and do the
following before replacing any FRUs.
1. Visually inspect the power cables and reseat the connectors.
2. Run the following command diag -Avd sysplanar0. When the Resource Repair
Action menu displays, select sysplanar0.
System shutdown due to loss of ac power to the site. Action: System resumed normal
operation, no action required.
Power fault due to manual activation of power-off request. Action: Resume normal
operation.
An over-temperature condition was detected. Action:
1. Make sure that:
v The room ambient temperature is within the system operating environment
v There is unrestricted air flow around the system
2. Replace the system-board and chassis assembly.
System shutdown due to an over maximum temperature condition being reached.
Action:
1. Make sure that:
v The room ambient temperature is within the system operating environment
v There is unrestricted air flow around the system
2. Replace the system-board and chassis assembly.
System shutdown due to over temperature condition and fan failure. Use the physical
FRU location(s) as the probable cause(s). Action: Use the physical location codes to
replace the FRUs that are identified on the diagnostics problem report screen.
Sensor detected a voltage outside of the normal range. Action: Go to "Performing the
checkout procedure" on page 106.
75
Chapter 2. Diagnostics