6. For problems affecting one or more of the removable media drives:
7. Check for correct management-module operation (see the documentation for
8. Replace the management module (see the documentation for your BladeCenter
If these steps do not resolve the problem, it is likely a problem with the blade
server. See "CD or DVD drive problems" on page 114 or "Universal Serial Bus
(USB) port problems" on page 123.
132
BladeCenter JS21 Types 7988 and 8844: Problem Determination and Service Guide
a. Reseat the following components:
1) Removable-media drive cable (if applicable)
2) Removable-media drive
3) Media tray cable (if applicable)
4) Media tray
b. Replace the following components one at a time, in the order shown,
restarting the blade server each time:
1) Removable-media drive cable (if applicable)
2) Media tray cable (if applicable)
3) Removable-media drive
4) Media tray
c. Continue with step 7.
your BladeCenter unit).
Note: Some BladeCenter unit types have several management-module
components that might need to be tested or replaced (see the Installation Guide
for your management module for more information).
unit).