v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Types 7988 and 8844," on page 137 to determine which components are
CRUs and which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
BA040040
BA040050
BA040060
BA050001
BA050004
BA05000A
BA060003
BA060004
BA060005
BA060008
BA06000B
BA06000C
BA060020
Description
Setting the machine type, model, and
serial number failed.
The h-call to switch off the boot
watchdog timer failed.
Setting the firmware boot side for the
next boot failed.
Failed to reboot a partition in logical
partition mode
Failed to locate service processor device
tree node.
Failed to send boot failed message
IP parameter requires 3 period
characters "."
Invalid IP parameter
Invalid IP parameter (>255)
No configurable adapters found by the
Remote IPL menu in the SMS utilities
The system was not able to find an
operating system on the devices in the
boot list.
A pointer to the operating system was
found in non-volatile storage.
The environment variable "boot-device"
exceeded the allowed character limit.
Action
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
Enter a valid IP parameter using the format:
XXX.XXX.XXX.XXX, where X is any digit 0 -
255.
Enter a valid IP parameter using the format:
XXX.XXX.XXX.XXX, where X is any digit 0 -
255.
Enter a valid IP parameter using the format:
XXX.XXX.XXX.XXX, where X is any digit 0 -
255.
This error occurs when the firmware cannot
locate any LAN adapters that are supported by
the remote IPL function. Make sure that the
devices in the remote IPL device list are correct
using the SMS menus.
Go to "Boot problem resolution" on page 112.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
1. Go to "Checkout procedure" on page 106.
2. Replace the system-board and chassis
assembly.
Chapter 2. Diagnostics