IBM BladeCenter JS21 Types 8844 Service Manual page 51

Problem determination and service guide
Hide thumbs Also See for BladeCenter JS21 Types 8844:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Types 7988 and 8844," on page 137 to determine which components are
CRUs and which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Attention code
AA06000D
AA06000E
AA060010
AA060011
AA100001
AA100002
AA130013
Description
The media in the device in the bootlist
was not found under the I/O adapter
specified by the bootlist.
The adapter specified in the boot list is
not present or is not functioning.
The FAT file system on the boot disk is
configured in a way that might cause a
boot failure.
The firmware did not find an operating
system image and at least one hard disk
in the boot list was not detected by the
firmware. The firmware is retrying the
entries in the boot list.
There was a communication failure
between partition firmware and the
hypervisor. The event that was expected
from the hypervisor was not received.
There was a communication failure
between partition firmware and the
hypervisor.
Bootable media is missing from a USB
CD-ROM
Action
1. Make sure that the media from which you
are trying to boot is bootable or modify the
boot list to boot from another bootable
device.
2. If the problem remains, go to "Boot problem
resolution" on page 112.
v For an AIX operating system:
1. Try booting the blade server from another
bootable device; then, run AIX online
diagnostics against the failing adapter.
2. If AIX cannot be booted from another
device, boot the blade server using the
Standalone Diagnostics CD or a NIM
server; then, run diagnostics against the
failing adapter.
v For a Linux operating system, boot the blade
server using the Standalone Diagnostics CD
or a NIM server; then, run diagnostics
against the failing adapter.
Increase the FAT partition size by 10% to keep
the number of data clusters fewer than
approximately 4080.
Make sure that:
v The boot disk belongs to the partition from
which you are trying to boot.
v The boot list in the SMS menus is correct.
1. Look at the error logs for errors that
occurred around the time that this attention
code was logged. Resolve those errors,
then reboot the blade server.
2. Go to "Checkout procedure" on page 106.
3. Replace the system board and chassis
assembly.
1. Look at the error logs for errors that
occurred around the time that this attention
code was logged. Resolve those errors,
then reboot the blade server.
2. Go to "Checkout procedure" on page 106.
3. Replace the system board and chassis
assembly.
Make sure that a bootable CD is properly
inserted in the CD or DVD drive and retry the
boot operation.
Chapter 2. Diagnostics
35

Advertisement

Table of Contents
loading

Table of Contents