SRN
FFC
110-101
110-921 to
812
110-926
xxx
110-935
812
110-xxxx
xxxx
221
111-107
111-108
111-121
111-78C
227
111-999
210
252B-101
252B
252B-710
252B
252B-711
252B
252B-712
252B
68
BladeCenter JS21 Types 7988 and 8844: Problem Determination and Service Guide
Description and action
The diagnostics did not detect an installed resource. Action: If this SRN appeared
when running concurrent diagnostics, then run concurrent diagnostics using the diag
-a command.
The system halted while diagnostics were executing.
Note: xxx corresponds to the last three digits of the SRN. Action: Go to general
checkout or problem resolution.
The system halted while diagnostics were executing. Action: Use the problem
determination procedure.
The system halted while diagnostics were executing.
Note: xxxx corresponds to the last three or four digits of the SRN following the dash
(-). If your 110 SRN is not listed, substitute the last three or four digits of the SRN for
xxxx, then proceed to the FFC table using the substituted digits as your FFC. Action:
Run standalone diagnostics, problem determination procedure for AIX and Linux. If
you still get the same SRN, refer to "Failing function codes" on page 104 to find the
FFC that matches the last three digits of the SRN.
A machine check occurred. Action: Go to "Performing the checkout procedure" on
page 106.
An encoded SRN was displayed. Action: Go to "Performing the checkout procedure"
on page 106.
There is a display problem. Action: Go to "Performing the checkout procedure" on
page 106.
PCI adapter I/O bus problem. Action: Go to "Performing the checkout procedure" on
page 106. Perform "Solving undetermined problems" on page 135.
System does not perform a soft reset. Action: Go to "Performing the checkout
procedure" on page 106.
Adapter configuration error.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Permanent adapter failure.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Adapter failure.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Adapter failure.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.