Error Log Analysis indicates permanent adapter failure is reported on the other port of
this adapter.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Error Log Analysis indicates permanent adapter failure is reported on the other port of
this adapter.
1. Check the BladeCenter management module event log. If an error was recorded
by the system or if a checkpoint code is displayed on the console, see "POST
checkpoint codes" on page 9.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board and chassis assembly.
Disk drive configuration failed.
The CEC reported a non-critical error. Action: Schedule deferred maintenance. Refer
to the problem determination procedure for this system, with the 8-digit error and
location codes, for the necessary repair action. If the 8-digit error and location codes
were NOT reported, then run AIX diagnostics in problem determination procedure and
record and report the 8-digit error and location codes for this SRN.
Display Character test failed.
Note: Diagnostic will provide this SRN but there is no action to be taken. Do not
perform operator panel test from diagnostics.
Sensor indicates a fan has failed. Action: Go to "Performing the checkout procedure"
on page 106.
Sensor indicates a voltage is outside the normal range. Go to "Performing the
checkout procedure" on page 106.
Sensor indicates an abnormally high internal temperature. Action: Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
Sensor indicates a power supply has failed. Action: Go to "Performing the checkout
procedure" on page 106.
Sensor indicates a FRU has failed. Action: use the failing function codes, use the
physical location code(s) from the diagnostic problem report screen to determine the
FRUs.