BladeCenter JS21 Types 7988 and 8844: Problem Determination and Service Guide
Description and action
Sensor detected an abnormally high internal temperature. Action: Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. There are no fan failures.
Sensor detected a voltage outside of the normal range. Go to "Performing the
checkout procedure" on page 106.
Sensor detected an abnormally high internal temperature. Action: Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
Platform-specific error. Action: Call your support center.
A non-critical error has been detected: uncorrectable memory or unsupported
memory. Action: Schedule deferred maintenance. Examine the memory modules and
determine if they are supported types. If the modules are supported, then replace the
appropriate memory modules.
A non-critical error has been detected: CPU internal error. Action: Schedule deferred
maintenance. Go to "Performing the checkout procedure" on page 106.
A non-critical error has been detected: CPU internal cache or cache controller error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: external cache parity or multi-bit ECC error.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: external cache ECC single-bit error. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: I/O expansion bus parity error. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: I/O expansion bus time-out error. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: I/O expansion bus connection failure. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: I/O expansion unit not in an operating state.
Action: Schedule deferred maintenance. Go to "Performing the checkout procedure"
on page 106.
A non-critical error has been detected: internal device error. Action: Schedule deferred
maintenance. Go to "Performing the checkout procedure" on page 106.
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.
A non-critical error has been detected: correctable error threshold exceeded. Action:
Schedule deferred maintenance. Go to "Performing the checkout procedure" on page
106.