SRN
Description
A05-04x
System shutdown due to voltage outside
normal range.
A05-05x
Sensor indicates an abnormally high internal
temperature.
A05-06x
System shutdown due to abnormally high
internal temperature.
A05-07x
Sensor indicates a power supply has failed.
A05-08x
System shutdown due to power supply
failure.
A05-10x
System shutdown due to FRU that has failed. 1. Check the BladeCenter management module event
FRU/action
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Make sure that:
a. The room ambient temperature is within the
system operating environment.
b. There is unrestricted air flow around the system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
3. If no entry is found, replace the system-board and
chassis assembly.
1. Make sure that:
a. The room ambient temperature is within the
system operating environment.
b. There is unrestricted air flow around the system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
3. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.