SRN
FFC
651-711
210
2C4
651-712
214
651-713
214
651-714
2C4
651-715
2C4
651-720
2C7
214
651-721
2C6
2C7
214
651-722
2C4
651-723
2C4
651-724
292
651-725
292
651-726
Software
651-731
2C8
651-732
2C8
651-733
2C8
651-734
292
651-735
292
651-736
292
651-740
2D3
651-741
2D3
651-742
2D3
651-743
2D5
651-745
2D9
651-746
2D4
651-747
2D5
651-748
2E2
651-750
2D4
651-751
2D4
651-752
2D4
651-753
151
2D4
651-770
292
651-771
292
651-772
292
651-773
227
74
BladeCenter JS21 Types 7988 and 8844: Problem Determination and Service Guide
Description and action
System bus parity error.
System bus parity error.
System bus protocol/transfer error.
System bus protocol/transfer error.
System bus protocol/transfer error.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
Uncorrectable memory error. Action: Go to "Performing the checkout procedure" on
page 106.
System bus parity error.
System bus protocol/transfer error.
I/O host bridge time-out error.
I/O host bridge address/data parity error.
I/O host bridge timeout caused by software. Action: This error is caused by a
software or operating system attempt to access an invalid memory address. Contact
software support for assistance.
Intermediate or system bus address parity error.
Intermediate or system bus data parity error.
Intermediate or system bus address parity error.
Intermediate or system bus data parity error.
Intermediate or system bus time-out error.
Intermediate or system bus time-out error.
Note: Ensure that the system IPLROS and service processor are at the latest
firmware level before removing any parts from the system.
Service processor error accessing special registers.
Service processor reports unknown communication error.
Service processor error accessing Vital Product Data EEPROM.
Service processor error accessing power controller.
Service processor error accessing fan sensor.
Service processor error accessing thermal sensor.
Service processor error accessing voltage sensor.
Service processor detected NVRAM error.
Service processor error accessing real-time clock/time-of-day clock.
Service processor error accessing JTAG/COP controller/hardware.
Service processor detects loss of voltage from the time-of-day clock backup battery.
Intermediate or system bus address parity error.
Intermediate or system bus data parity error.
Intermediate or system bus time-out error.
Intermediate or system bus data parity error.