IBM BladeCenter JS21 Types 8844 Service Manual page 54

Problem determination and service guide
Hide thumbs Also See for BladeCenter JS21 Types 8844:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Types 7988 and 8844," on page 137 to determine which components are
CRUs and which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
B2002485
B2003081
B2003125
B2006006
B2006012
B2006027
B200690A
B2008080
B2008081
B2008105
B2008107
B2008109
B2008112
38
BladeCenter JS21 Types 7988 and 8844: Problem Determination and Service Guide
Description
During the startup of a partition, the
partition firmware attempted an operation
that failed.
During the startup of a partition, the
startup did not complete due to a copy
error.
During the startup of a partition, the
blade server firmware could not obtain a
segment of main storage within the
blade server to use for managing the
creation of a partition.
During the startup of a partition, a
system firmware error occurred when the
partition memory was being initialized;
the startup will not continue.
During the startup of a partition, the
partition LID failed to completely load
into the partition main storage area.
During the startup of a partition, a failure
occurred when allocating memory for an
internal object used for firmware module
load operations.
During the startup of a partition, an error
occurred while copying open firmware
into the partition load area.
System log entry only.
During the startup of a partition, an
internal firmware time-out occurred; the
partition may continue to start up but it
may experience problems while running.
During the startup of a partition, there
was a failure loading the VPD areas of
the partition; the load source media has
been corrupted or is unsupported on this
server.
During the startup of a partition, there
was a problem getting a segment of
main storage in the blade server main
storage.
During the startup of a partition, a failure
occurred; the startup will not continue.
During the startup of a partition, a failure
occurred; the startup will not continue.
Action
Go to "Firmware problem isolation" on page
127.
Check for server firmware updates; then, install
the updates if available.
Check for server firmware updates; then, install
the updates if available.
Go to "Firmware problem isolation" on page
127.
Go to "Firmware problem isolation" on page
127.
1. Make sure that enough main storage was
allocated to the partition.
2. Retry the operation.
Go to "Firmware problem isolation" on page
127.
No service action required.
Check for server firmware updates; then, install
the updates if available.
Check for server firmware updates; then, install
the updates if available.
Check for server firmware updates; then, install
the updates if available.
1. Make sure that there is enough memory to
start up the partition.
2. Check for server firmware updates; then,
install the updates if available.
Check for server firmware updates; then, install
the updates if available.