SRN
FFC
651-632
308
651-639
210
651-640
2D5
651-641
2D6
651-642
2D3
651-643
2D3
651-644
2D3
651-659
2CD
651-65A
2CE
651-65B
2CC
651-664
302
651-665
303
651-666
304
651-669
2CD
651-66A
2CE
651-66B
2CC
651-674
302
651-675
303
651-676
304
651-679
2CD
651-67A
2CE
651-67B
2CC
651-685
303
651-686
304
651-710
214
2C4
Description and action
Internal device error.
Error log analysis indicates an error detected by the I/O. Action: Use the problem
determination procedure and failing function codes, use the physical location codes
from the diagnostic problem report screen to determine the FRUs.
I/O general bus error.
Secondary I/O general bus error.
Internal service processor memory error.
Internal service processor firmware error.
Other internal service processor hardware error.
ECC correctable error. Action: Go to "Performing the checkout procedure" on page
106.
ECC correctable error. Action: Go to "Performing the checkout procedure" on page
106.
ECC correctable error. Action: Go to "Performing the checkout procedure" on page
106.
Correctable error threshold exceeded. Action: Go to "Performing the checkout
procedure" on page 106.
Correctable error threshold exceeded. Action: Go to "Performing the checkout
procedure" on page 106.
Correctable error threshold exceeded. Action: Go to "Performing the checkout
procedure" on page 106.
Correctable error threshold exceeded. Action: Go to "Performing the checkout
procedure" on page 106.
Correctable error threshold exceeded. Action: Go to "Performing the checkout
procedure" on page 106.
Correctable error threshold exceeded. Action: Go to "Performing the checkout
procedure" on page 106.
Failed memory module. Action: Go to "Performing the checkout procedure" on page
106.
Failed memory module. Action: Go to "Performing the checkout procedure" on page
106.
Failed memory module. Action: Go to "Performing the checkout procedure" on page
106.
Failed memory module. Action: Go to "Performing the checkout procedure" on page
106.
Failed memory module. Action: Go to "Performing the checkout procedure" on page
106.
Failed memory module. Action: Go to "Performing the checkout procedure" on page
106.
Memory module has no matched pair. Action: The most probable failure is the
memory module paired with the memory module identified by the location code. Go to
"Performing the checkout procedure" on page 106.
Memory module has no matched pair. Action: The most probable failure is the
memory module paired with the memory module identified by the location code. Go to
"Performing the checkout procedure" on page 106.
System bus parity error.
73
Chapter 2. Diagnostics
Need help?
Do you have a question about the BladeCenter JS21 Types 8844 and is the answer not in the manual?