SRN
Description
A1D-31x
A non-critical error has been detected: Error
detected while handling an attention/interrupt
from the system hardware.
A1D-34x
A non-critical error has been detected: Wire
Test Error.
A1D-35x
A non-critical error has been detected:
Mainstore or Cache IPL Diagnostic Error.
A1D-37x
A non-critical error has been detected: Clock
or PLL Error.
A1D-38x
A non-critical error has been detected:
Hardware Scan or Initialization Error.
A1D-40x
A non-critical error has been detected:
Presence/Detect Error (Mis-Plugged).
A1D-50x
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The system is
operating with the potential for an
unrecoverable error.
FRU/action
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
2. If no entry is found, replace the system-board and
chassis assembly.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the BladeCenter management module event
log; if an error was recorded by the system or if a
checkpoint code is displayed on the console, see
"POST checkpoint codes" on page 9.
3. If no entry is found, replace the system-board and
chassis assembly.