Pause mode
If the SMPTE clock is running, press [More Softkeys] [S4], Pause,
to interrupt the SMPTE clock when you are programming the
console. While in Pause mode, the Step softkey lets you manually
control playback of SMPTE events.
Keystrokes:
1. Press [Setup*].
2. Press [9], SMPTE Events,
[Enter].
3. Press [More Softkeys].
4. Press [S5], Step. (Step only
appears on the softkey in
Pause Mode)
5. Repeat step 4 to advance
through SMPTE events.
6. Use Set Time to change the
current time, then press [S5],
Step. See page 307 for
instructions on setting the
time.
External SMPTE source
Once you record a series of eve ts n a SMPTE program, the
console automatically runs the program in response to SMPTE
time code. To run the SMPTE program, enter Run Mode and start
the flow of external SM TE data. Make sure External SMPTE
Input is enabled.
Note: In Full Tr king Backup systems, the SMPTE signal must be
sent to both he Master and the Backup systems to provide
redundancy. Si ce SMPTE cannot be 'Y'ed, and your output
device as only one port, you must use a SMPTE splitter.
Obsession User Manual
Action/Command line:
Selects SMPTE Events display
Advances to the next recorde
SMPTE event
Causes the next event after the
new current time to execute.