Check loads
Load Check compares the current load with the recorded load.
Loads that differ by more than 20 percent appear in the Load
Management display. To identify the dimmer(s) to check, use
either the CEM or the Obsession to set the desired dimmers at a
level above zero.
The system checks 24 dimmers per rack at a time until all
dimmers at levels above zero have been checked. (If you have
multiple racks, 24 dimmers in each rack are checked simulta-
neously.)
Note: On single phase racks, the system checks 16 dimmers per
rack at a time.
Caution: Load Check changes levels on stage. Dimmer outputs
rise and fall for several minutes during the procedure. To cancel a
check load operation, press [S6], Load Check, [–] [Enter]
Keystrokes:
1
Set dimmers to be checked
to a level above zero. Only
dimmers above zero are
checked
2. Press [Setup*].
3
Press [1][1], Dimmer
Monitoring, [Enter].
4. Press [4], Load Manag
ment, [Enter].
5. Press [S6], Load Ch ck.
(You may enter specif c
dimmers to ch ck.)
6. Press [En er]
7. Press [Enter] to proceed
wi h the load check, or press
[Cle r] to cancel.
Obsession User Manual
Action/Command line:
Sele t Dimmer Monitoring
m nu
Selects Load Management
display
Load Management: LOAD
CHECK
Load Management: LOAD
CHECK Please Confirm
Loads are checked for all
dimmers with levels above
zero Load Management:
LOAD CHECK Please
Confirm