Chapter 22 Sensor dimming
Record loads
Record Loads records 24 dimmers per rack at a time until all
dimmers at levels above zero have been recorded. (If you have
multiple racks, 24 dimmers in each rack are recorded simulta-
neously.)
Note: On single phase racks, the system records 16 dimmers per
rack at a time.
Caution: Record Loads changes levels on stage. Dimmer outputs
rise and fall for several minutes during the procedure. To cancel a
record load operation, press [S2], Record Loads, [–] [Enter].
Keystrokes:
1. Set dimmers to be recorded
to a level above zero. Only
dimmers above zero are
recorded
2. Press [Setup*].
3
Press [1][1], Dimmer Moni-
toring, [Enter].
4. Press [4], Load Manage-
ment, [Enter].
5. Press [S2], Record Loads. If
you wish, enter a specific
dimmer or dimmers to
record.
6. Press [Enter].
7. Press [Enter] to proceed
with the load rec rd, or press
[Clear] to can el.
Action/Command line:
Selects Dimme Monitoring
menu
Selects Load Management
display
Lo d Management:
ECORD LOADS
Load Management: RECORD
LOADS
Please Confirm
New loads are recorded for all
dimmers with levels above
zero
Load Management: RECORD
LOADS
Please Confirm
279