4.3.5
Supply Voltage
Nominal value: 24 V DC (11 ... 30 V, P < 6 W).
►
Only turn on the power supply after wiring has been completed.
►
Connect inputs "9" and "2" on the 12-pin M12 female connector to a 24 V power supply
power | rs422
12-pin M12 female con
nector, pin
9
2
Fig. 4.5: Supply voltage connection
Voltage supply only for measuring devices, not to be used for drives or similar sources of impulse interference at the
same time. Micro-Epsilon recommends using an optional available power supply unit PS2020 for the sensor.
4.3.6
Analog Output
The sensor offers the following alternatives:
A 4 ... 20 mA current output
●
A 0 ... 5 V or 0 ... 10 V voltage output
●
i
The current output must not be used continuously in short-circuit operation without a load. Continuous
short-circuit operation leads to thermal overloading and thus causes the output to switch off automati
cally.
►
Connect outputs 1 (white, inner coaxial conductor) and 2 (black, coaxial shield) on the 12-pin M12 female connector
to a measuring device.
in | out
17-pin M12 male connec
tor, pin
1
2
Fig. 4.6: Analog output switching
Current output
R
V
max. = 250 ohms at
B
+
R
V
max. = 500 ohms at
B
+
optoCONTROL 2700
PC/SC2700-x
Signal
Wire color
V
Red
+
Blue
GND
SCA2700-x
Wire color
White
ODC2700
Black
ODC2700
Voltage output
R
> 11 V
= 50 ohms
i
R
> 17 V
> 100 kilohms
L
9
11 ...
30 VDC
ODC2700
ODC2700
12-pol M12
12-pin M12
2
I
out
1
C
R
B
2
1
R
i
V
C
R
out
L
2
I
V
Installation and Assembly
Seite 24