12.10
Measurement
12.10.1
Selecting the Measuring Program
MEASMODE EDGEHL|EDGELH|DIA|GAP|SEGMENT
Defines the measuring program.
EDGEHL: Light-dark edge; position of first light-dark edge
●
EDGELH: Dark-light edge; position of the first dark-light edge
●
DIA: Diameter (distance from first light-dark edge to dark-light edge) and position of the diameter center axis
●
GAP: Gap (distance from first dark-light edge to light-dark edge) and position of the gap center axis
●
SEGMENT: Segment (difference between the two selected edges and positions of the various center axes)
●
See DEFSEG1...DEFSEG8
The position is the distance to the beginning of the line (see MEASDIR).
12.10.2
Edge Search Direction
SEARCHDIR STANDARD|INVERSE
Sets the edge search direction.
STANDARD: Searches for edges by moving away from the mounting rail (the first edge is the one next to the mounting
●
rail)
INVERSE: Searches for edges by moving toward the mounting rail (the first edge is the one furthest away from the
●
mounting rail)
12.10.3
Measurement Direction
MEASDIR STANDARD|INVERSE
Sets the measurement direction for the edges.
STANDARD: The measurement direction begins at the start of the measuring range (SMR, mounting rail) and moves
●
toward the end of the measuring range.
INVERSE: The measurement direction begins at the end of the measuring range (EMR) and moves toward the start of
●
the measuring range (mounting rail).
12.10.4
Number of Expected Edges
EXPEDGES <value>
Defines the number of expected edges for the ERROROUT command.
Value: 0 ... 251
●
optoCONTROL 2700
ASCII Communication
Seite 90
Need help?
Do you have a question about the optoCONTROL 2700 and is the answer not in the manual?