Sign In
Upload
Manuals
Brands
MICRO-EPSILON Manuals
Industrial Equipment
optoNCDT 1420
MICRO-EPSILON optoNCDT 1420 Manuals
Manuals and User Guides for MICRO-EPSILON optoNCDT 1420. We have
2
MICRO-EPSILON optoNCDT 1420 manuals available for free PDF download: Operating Instructions Manual, Assembly Instructions
MICRO-EPSILON optoNCDT 1420 Operating Instructions Manual (129 pages)
Brand:
MICRO-EPSILON
| Category:
Measuring Instruments
| Size: 7 MB
Table of Contents
Table of Contents
3
1 Safety
9
Symbols Used
9
Warnings
9
Notes on CE Marking
10
Notes on UKCA Marking
11
Intended Use
11
Proper Environment
11
2 Laser Safety
12
Ild1420 / Ild1420Ll
12
Ild1420 Cl1
14
3 Functional Principle, Technical Data
16
Short Description
16
Auto Target Compensation (ATC)
17
Technical Data ILD1420
18
Technical Data ILD1420LL
20
Technical Data ILD1420-CL1
22
4 Delivery
24
Unpacking, Included in Delivery
24
Storage
24
Structure of the Serial Number
24
5 Installation
25
Notes for Operation
25
Reflection Factor of the Target Surface
25
Error Influences
25
Light from Other Sources
25
Color Differences
26
Temperature Influences
26
Mechanical Vibration
26
Movement Blurs
26
Surface Roughness
27
Angle Influences
28
Optimizing the Measuring Accuracy
29
Mounting, Dimensions
30
Indicator Elements at Sensor
32
Electrical Connections
33
Connection Possibilities
33
Pin Assignment
35
Supply Voltage
36
Laser on
36
Analog Output
37
Multifunctional Input
38
RS422 Connection with USB Converter IF2001/USB
38
Digital Output
39
Connector and Sensor Cable
40
6 Operation
41
Getting Ready for Operation
41
Operation Via Web Interface
42
Preconditions
42
Access Via Web Interface
43
Calibration Protocol
44
Presets, Setups, Measurement Configuration, Signal Quality
45
Measurement Presentation Via Web Browser
47
Video Signal Via Web Browser
49
Programming Via ASCII Commands
51
Timing, Measurement Value Flux
51
7 Set Sensor Parameter
52
Preliminary Remarks to the Adjustments
52
Overview Parameter
52
Inputs
53
Signal Processing
53
Preliminary Remark
53
Measurement Task
54
Measuring Rate
55
Triggering
56
General
56
Signal Processing - Trigger for Acquiring Values
58
Signal Processing - Value Output Trigger
58
Mask Evaluation Area, ROI
59
Peak Selection
60
Error Handling
60
Averaging
61
General
61
Moving Average
62
Recursive Average
63
Median
63
Zeroing and Mastering
64
Zeroing, Mastering with Select Key
65
Zeroing, Mastering with Hardware Input
66
Data Reduction, Output Data Rate
67
Outputs
68
Overview
68
Digital Output, RS422
69
Analog Output Scaling
70
Output Scaling
70
Output Scaling with Key Select
71
Output Scaling Via Hardware Input
72
Calculation of Measuring Value Using Analog Current
73
Characteristics Distance Value and Analog Output
75
Mastering and Teaching Analog Output
77
System Settings
78
General
78
Unit, Language
78
Keylock
79
Load, Save
80
Import, Export
82
Access Authorization
83
Sensor Reset
84
8 Digital Interfaces RS422
85
Preliminary Remarks
85
Measurement Data Format
85
Conversion of the Binary Data Format
86
Values, Ranges
87
Characteristics Digital Output
89
9 Cleaning
91
10 Software Support with Medaqlib
92
11 Disclaimer
93
12 Service, Repair
93
13 Decommissioning, Disposal
94
Appendix
95
A 1 Optional Accessories
95
A 2 Factory Setting
99
A 3 ASCII Communication with Sensor
100
A 3.1 General
100
A 3.2 Overview Commands
102
A 3.3 General Commands
105
A 3.3.1 Help
105
A 3.3.2 GETINFO, Sensor Information
105
A 3.3.3 LANGUAGE, Website
105
A 3.3.4 RESET, Boot Sensor
106
A 3.3.5 RESETCNT, Reset Counter
106
A 3.3.6 ECHO, Switching the Command Reply, ASCII Interface
106
A 3.3.7 PRINT, Sensor Settings
107
A 3.3.8 User Level
108
A 3.3.8.1 LOGIN, Change of the User Level
108
A 3.3.8.2 LOGOUT, Change into User Level
108
A 3.3.8.3 GETUSERLEVEL, User Level Request
108
A 3.3.8.4 STDUSER, Set Standard User
108
A 3.3.8.5 PASSWD, Change Password
108
A 3.3.9 Triggering
109
A 3.3.9.1 TRIGGER, Selection
109
A 3.3.9.2 TRIGGERAT, Effect of the Trigger Input
109
A 3.3.9.3 MFILEVEL, Input Pulse Multifunctional Input
109
A 3.3.9.4 TRIGGERCOUNT, Number of Displayed Measurement Values
109
A 3.3.9.5 TRIGGERSW, Software Trigger Pulse
110
A 3.3.10 Interfaces
110
A 3.3.10.1 Baudrate, Rs422
110
A 3.3.10.2 UNIT, Web Interface
110
A 3.3.10.3 MFIFUNC, Function Selection Multifunctional Input
110
A 3.3.10.4 ERROROUT1, Activate Digital Output
110
A 3.3.10.5 ERRORLEVELOUT1, Output Level Digital Output
111
A 3.3.10.6 Errorlimit
111
A 3.3.10.7 Errorhysteresis
111
A 3.3.10.8 Errorouthold
111
A 3.3.11 Handling of Setups
112
A 3.3.11.1 Import
112
A 3.3.11.2 MEASSETTINGS, Load / Save Measurement Settings
112
A 3.3.11.3 BASICSETTINGS, Load / Save Device Settings
113
A 3.3.11.4 SETDEFAULT, Default Settings
113
A 3.3.12 ANALOGSCALE, Scaling the Analog Output
113
A 3.3.13 Key Function
114
A 3.3.13.1 KEYFUNC, Choose Key Function
114
A 3.3.13.2 KEYLOCK, Set Keylock
114
A 3.4 Measurement
114
A 3.4.1 TARGETMODE, Measurement Mode
114
A 3.4.2 MEASPEAK, Choice of the Peak in the Video Signal
114
A 3.4.3 MEASRATE, Measuring Rate
115
A 3.4.4 LASERPOW, Laser Power
115
A 3.4.5 ROI, Video Signal, Masking the Region of Interest (ROI)
115
A 3.4.6 Measurement Value Processing
115
A 3.4.6.1 AVERAGE, Measurement Value
115
A 3.4.6.2 MASTERMV, Mastering / Zeroing
116
A 3.5 Data Output
116
A 3.5.1 OUTPUT, Selection of Measurement Value Output
116
A 3.5.2 OUTREDUCEDEVICE, Output Reduction of Measurement Value Output
116
A 3.5.3 OUTREDUCECOUNT, Output Data Rate
116
A 3.5.4 OUTHOLD, Error Processing
117
A 3.5.5 Selection of Measurement Values to be Output
117
A 3.5.5.1 GETOUTINFO_RS422, Request Data Selection
117
A 3.5.5.2 OUTADD_RS422, Selection of Data Additional Values
117
A 3.5.5.3 OUTVIDEO_RS422, Adjust Video Output
117
A 3.6 Example Command Sequence During Selection of Measurement Value
118
A 3.7 Error Messages
118
A 4 Control Menu
120
A 4.1 Tab Home
120
Tab Settings
121
Inputs
121
Signal Processing
121
Outputs
123
System Settings
125
Advertisement
MICRO-EPSILON optoNCDT 1420 Assembly Instructions (2 pages)
Protective Film
Brand:
MICRO-EPSILON
| Category:
Industrial Equipment
| Size: 0 MB
Advertisement
Related Products
MICRO-EPSILON ELTROTEC Endolight FOT Halogen 150
MICRO-EPSILON thicknessSENSOR 10/200
MICRO-EPSILON thicknessSENSOR 10/400
MICRO-EPSILON optoNCDT 1220-IO
MICRO-EPSILON ILD 1220-10-IO
MICRO-EPSILON ILD 1220-25-IO
MICRO-EPSILON ILD 1220-50-IO
MICRO-EPSILON ILD 1220-100-IO
MICRO-EPSILON ILD 1220-200-IO
MICRO-EPSILON ILD 1220-500-IO
MICRO-EPSILON Categories
Measuring Instruments
Accessories
Industrial Equipment
Controller
Security Sensors
More MICRO-EPSILON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL