Retrieving Sensor Information; Reply Type; Parameter Overview - MICRO-EPSILON optoCONTROL 2700 Operating Instructions Manual

Hide thumbs Also See for optoCONTROL 2700:
Table of Contents

Advertisement

[]: Optional parameter
<>: Placeholder
|: List
If a parameter contains spaces, it must be placed inside quotation marks.
Examples
a|b: Use either a or b
a b: Both parameters are required
a [b [c]]: Any number of parameters: a, a b, or a b c
IPCONFIG DHCP|(STATIC [<IPAddress> [<Netmask> [<Gateway>]]])
Defines the Ethernet interface. You can select DHCP or STATIC with further parameters. If you define the gateway, you
must also specify the IP address, its type, and the net mask.
PASSWD <Old password> <New password> <New password>
To change the password, all parameters are required.
12.2.2

Retrieving Sensor Information

GETINFO
Outputs information regarding the sensor.
Fig. 12.1: Response of Sensor to GETINFO
12.2.3

Reply type

ECHO [ON|OFF]
The reply type describes the structure of a command reply. In read mode, the command name is always output.
ON: The command name and the command reply or an error message is output.
OFF: Nothing but the command reply or an error message is output.
12.2.4

Parameter overview

PRINT [ALL]
This command outputs a complete or partial list of all configuration parameters and their values.
optoCONTROL 2700
ASCII Communication
Seite 81